Understand fire classification and performance declarations

To assign the Euroclasses, 2 tests are carried out: ◼the small flame test (NF EN ISO 11925-2) : The objective is to evaluate the ignitability of a product exposed to a thermal solicitation weak and localized, simulated by a small flame. ◼european radiant panel test (NF EN ISO 9239-1) : The objective is to determine the critical radiant flux from which a flame front stopp to propagate on a horizontal surface consisting of a flooring sample. EUROCLASSES Test methods 8 Euroclasseset DOP-01-2021